Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Prostate Cancer Prostatic Dis ; 7(2): 170-7, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15136786

RESUMO

INTRODUCTION AND OBJECTIVES: The efficacy of adjuvant and salvage external beam radiation (AXRT+SXRT) for prostate cancer after radical prostatectomy (RP) has been debated because of the inability to rule out systemic occult metastasis, uncertainty that radiation eradicates residual local disease and the potential of exacerbating impotency and incontinence. To characterize the effectiveness and treatment morbidity a retrospective review was performed. METHODS: In all, 38 patients received AXRT and 91 received SXRT. The SXRT group was stratified by PSA level, age, race, pathologic stage, margin status, worst Gleason sum, radiation dose and pelvic field. Complications evaluated were impotence and incontinence. Median follow-up was 60.2 months. RESULTS: The 5-y disease-free survival (DFS) rate was 61.3% for AXRT and 36.3% for SXRT. Multivariate analysis of the SXRT cohort showed Gleason score, pathologic stage and pre-XRT PSA to be predictors of disease recurrence. After XRT 26% had worsened continence. CONCLUSIONS: Patients who recur after RP whose pathologic stage is pT2 or pT3c, Gleason score of 8 or higher or pre-XRT PSA is >2.0 ng/dl may have microscopic metastatic disease and a decreased chance of cure with SXRT alone. Continence was further impaired after XRT.


Assuntos
Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Prostatectomia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Lesões por Radiação , Idoso , Intervalo Livre de Doença , Disfunção Erétil/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Neoplasias da Próstata/patologia , Radioterapia Adjuvante/efeitos adversos , Estudos Retrospectivos , Terapia de Salvação , Incontinência Urinária/etiologia
2.
Med Dosim ; 22(3): 185-91, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9307948

RESUMO

The dose to the contralateral breast has been associated with an increased risk of developing a second breast malignancy. Varying techniques have been devised and described in the literature to minimize this dose. Metal beam modifiers such as standard wedges are used to improve the dose distribution in the treated breast, but unfortunately introduce an increased scatter dose outside the treatment field, in particular to the contralateral breast. The enhanced dynamic wedge is a means of remote wedging created by independently moving one collimator jaw through the treatment field during dose delivery. This study is an analysis of differing doses to the contralateral breast using two common clinical set-up techniques with the enhanced dynamic wedge versus the standard metal wedge. A tissue equivalent block (solid water), modeled to represent a typical breast outline, was designed as an insert in a Rando phantom to simulate a standard patient being treated for breast conservation. Tissue equivalent material was then used to complete the natural contour of the breast and to reproduce appropriate build-up and internal scatter. Thermoluminescent dosimeter (TLD) rods were placed at predetermined distances from the geometric beam's edge to measure the dose to the contralateral breast. A total of 35 locations were used with five TLDs in each location to verify the accuracy of the measured dose. The radiation techniques used were an isocentric set-up with co-planar, non divergent posterior borders and an isocentric set-up with a half beam block technique utilizing the asymmetric collimator jaw. Each technique used compensating wedges to optimize the dose distribution. A comparison of the dose to the contralateral breast was then made with the enhanced dynamic wedge vs. the standard metal wedge. The measurements revealed a significant reduction in the contralateral breast dose with the enhanced dynamic wedge compared to the standard metal wedge in both set-up techniques. The dose was measured at varying distances from the geometric field edge, ranging from 2 to 8 cm. The average dose with the enhanced dynamic wedge was 2.7-2.8%. The average dose with the standard wedge was 4.0-4.7%. Thermoluminescent dosimeter measurements suggest an increase in both scattered electrons and photons with metal wedges. The enhanced dynamic wedge is a practical clinical advance which improves the dose distribution in patients undergoing breast conservation while at the same time minimizing dose to the contralateral breast, thereby reducing the potential carcinogenic effects.


Assuntos
Neoplasias da Mama/radioterapia , Mama/efeitos da radiação , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador , Feminino , Humanos , Imagens de Fantasmas , Doses de Radiação , Dosagem Radioterapêutica , Dosimetria Termoluminescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...